The workhorse alloy: alpha-beta, heat-treatable, roughly twice the strength of Gr2 at almost the same density. If your part is load-bearing, runs above 300 °C, or is thin-walled and being machined, this is the grade people specify — and the one most often specified wrongly.
Per ASTM B348 / B265, mass %. These are range limits, not targets.
| Element | Min % | Max % | Why it matters |
|---|---|---|---|
| Aluminium | 5.50 | 6.75 | Alpha stabiliser — strength and oxidation resistance |
| Vanadium | 3.50 | 4.50 | Beta stabiliser — ductility and hardenability |
| Iron | — | 0.30 | Excess iron embrittles; a common cheap-heat tell |
| Oxygen | — | 0.25 | Raises strength, cuts ductility and machinability |
| Carbon | — | 0.08 | Interstitial strengthener; watch on repeat heats |
| Nitrogen | — | 0.05 | Small effect, tightly held |
| Hydrogen | — | 0.015 | Hydride risk if it climbs |
| Titanium | — | bal. | Remainder |
Gr23 (ELI) is the same alloy with oxygen capped at 0.13 % and iron at 0.25 %. That difference is the entire reason it behaves better in thin machined sections.
| Property | Metric | Imperial | Method | Condition |
|---|---|---|---|---|
| Tensile strength, UTS | ≥ 895 MPa | ≥ 130 ksi | ASTM E8 | Mill annealed |
| Yield strength, Rp0.2 | 828 MPa typ. | 120 ksi | ASTM E8 | Mill annealed |
| Elongation A | 10 % | 10 % | ASTM E8 | Mill annealed |
| Reduction of area | 30 % | 30 % | ASTM E8 | Mill annealed |
| Hardness | 364 HB typ. | ≈ 38 HRC | ASTM E10 | Mill annealed |
| Modulus of elasticity | 110 GPa | 16 Msi | ASTM E111 | Room temperature |
| Fatigue strength (10⁷ cycles) | ≈ 483 MPa | 70 ksi | ASTM E466 | Smooth bar, R = −1 |
| Fracture toughness KIC | 66 MPa·m½ | 60 ksi·in½ | ASTM E399 | Aged plate |
| Density | Melting range | β transus | Thermal cond. | Specific heat | CTE 20–200 °C | Resistivity |
|---|---|---|---|---|---|---|
| 4.43 g/cm³ 0.160 lb/in³ | 1604–1660 °C | ≈ 995 °C | 6.7 W/m·K | 526 J/kg·K | 8.6 µm/m·K | 170 µΩ·cm |
Same grade, different specification depending on what you are buying. This is where most mis-quotes start.
| Form | ASTM / ASME | DIN / EN | GB | GOST | Aerospace |
|---|---|---|---|---|---|
| Plate & sheet | B265 Gr5 | 3.7164 / TA6V | GB/T 3621 TC4 | ВТ6 | AMS 4911 |
| Seamless tube | B337 Gr5 | 3.7034 | GB/T 3625 | ВТ6 | AMS 4928 |
| Welded tube | B338 | — | GB/T 3625 | — | AMS 4929 |
| Bar, billet, forgings | B348 Gr5 | 3.7164 | GB/T 2965 | ВТ6 | AMS 4928 / 4965 |
| Wire | B863 Gr5 | — | GB/T 3629 | — | AMS 4919 |
| Fittings | B367 Gr2 (Ti-6Al-4V) | — | GB/T 13678 | — | ASME B16.9 |
| Flanges | B381 F5 | — | NB/T 47010 | — | ASME B16.5 |
| Fasteners | F1341 | DIN 6923 (mat.) | GB/T 3099.1 | — | NAS 1803 / MS21245 |
| UNS | Trade / regional | Chinese | Russian | European | Japanese |
|---|---|---|---|---|---|
| R56400 | Ti-6Al-4V · Timetal 6-4 · VST5-1 | TC4 / TA6V | ВТ6 (VT6) | 3.7164 / TA6V | Ti-6Al-4V (JIS H 4603) |
Equivalence is by composition and strength class, not by guaranteed performance. Verify against the governing specification for your application.
| Form / grade | Size | Standard | On floor | FOB USD/kg | Ship within |
|---|---|---|---|---|---|
| Gr5 (TC4) bar | Ø60 mm drawn | ASTM B348 | 41 t | 12.40 | 7 days |
Stock figures refreshed 2026-11-01. Blank cells mean we do not hold that form — ask and we will quote a rolling slot instead.
Gr5 is harder to cut and less forgiving at small sections than Gr23. If you are CNC-ing something under about 6 mm wall, run the tool-life maths before you commit — the ELI premium usually pays for itself in one avoided scrapped batch.
Alloying for strength costs a little corrosion margin versus CP grades. In hot chloride or reducing-acid service, Gr7 or Gr2 is often the cheaper answer over the asset's life, even though the per-kg price looks worse.
Mill-annealed and solution-treated-plus-aged give very different numbers from the same heat. If your PO says “895 MPa min” without a condition, we will quote mill annealed and you may receive a part that fails a proof test.
Yes in composition and strength class. TC4 is the Chinese GB designation; both map to UNS R56400. What is not the same is the tolerance band and the test set required by GB/T 2965 versus ASTM B348.
Yes, but tell us before we machine. Solution treating plus ageing distorts thin sections, and a finished ±0.02 mm bearing journal will not survive it without a straightening pass.
For implant duty specify Gr23 / F136 or F67, not Gr5. We supply ELI bar with per-heat traceability, and we will not substitute Gr5 for a F136 requirement.
500 kg from stock, cut to length. Below that, shearing setup makes the unit price unreasonable.
Datasheet PDF is email-gated. One email, no newsletter.